Search results for "Prosthetic heart"

showing 3 items of 3 documents

Improved Assessment of Pathological Regurgitation in Patients with Prosthetic Heart Valves by Multiplane Transesophageal Echocardiography

1997

The aim of this study was to evaluate the diagnostic increment of individually optimized axes in the assessment of pathological prosthetic valve regurgitation. Forty-two patients with pathologically regurgitant prostheses in the aortic (n = 21), mitral (n = 15), and tricuspid (n = 6) positions were examined by multiplane transesophageal echocardiography. The investigation was performed utilizing the transverse axis first, the longitudinal axis second, and the intermediate axes afterwards. The presence of regurgitation, the differentiation between trans- and perivalvular origin, and the localization of perivalvular leakages at the sewing ring were evaluated. Findings in the biplane and inter…

Prosthetic valvemedicine.medical_specialtybusiness.industryPeriprostheticRegurgitation (circulation)BiplanemedicineRadiology Nuclear Medicine and imagingIn patientRadiologyCardiology and Cardiovascular MedicineLongitudinal axisbusinessPathologicalProsthetic heartEchocardiography
researchProduct

In-vitro-Untersuchung von biologischen und technischen Herzklappenprothesen im MRT: Beurteilung möglicher Anziehung und Erhitzung der Implantate

2000

PURPOSE In vitro evaluation of possible deflection and heating of present-day prosthetic heart valves during MR imaging at 1.5 T. METHODS 17 prosthetic heart valves, 12 technical and 5 biological, were investigated using a 1.5 Tesla Siemens Vision system. Deflection was measured at the edge of a 1.5 Tesla superconducting magnet. Each valve was then submerged in a vial of a 1/1 electrolyte solution and temperature was measured before and after imaging with a turbo-spin-echo sequence (TR 5200 ms, TE 138 ms, Flip angle 180 degrees, acquisition time 10.5 minutes, length of echo train 29). MR imaging was performed with phase encoding parallel and perpendicular to the plane of the valves. RESULTS…

medicine.medical_specialtyMaterials sciencemedicine.diagnostic_testmedicine.medical_treatmentMagnetic resonance imagingBiological effectMr imagingProsthesisSurgerymedicine.anatomical_structureFlip anglemedicineRadiology Nuclear Medicine and imagingAcquisition timeHeart valveBiomedical engineeringProsthetic heartRöFo - Fortschritte auf dem Gebiet der Röntgenstrahlen und der bildgebenden Verfahren
researchProduct

Pre-Operative Modeling of Transcatheter Mitral Valve Replacement in a Surgical Heart Valve Bioprosthesis

2020

Obstruction of the left ventricular outflow tract (LVOT) is a common complication of transcatheter mitral valve replacement (TMVR). This procedure can determine an elongation of an LVOT (namely, the neo-LVOT), ultimately portending hemodynamic impairment and patient death. This study aimed to understand the biomechanical implications of LVOT obstruction in a patient who underwent TMVR using a transcatheter heart valve (THV) to repair a failed bioprosthetic heart valve. We first reconstructed the heart anatomy and the bioprosthetic heart valve to virtually implant a computer-aided-design (CAD) model of THV and evaluate the neo-LVOT area. A numerical simulation of THV deployment was then deve…

medicine.medical_specialtytranscatheter mitral valve replacementmedicine.medical_treatment0206 medical engineeringHemodynamics02 engineering and technology030204 cardiovascular system & hematologybioprosthetic heart valve03 medical and health sciences0302 clinical medicinefinite-element analysiInternal medicinemedicineVentricular outflow tractHeart valvebusiness.industryHeart anatomyMitral valve replacementGeneral Medicine020601 biomedical engineeringPre operativemedicine.anatomical_structureCardiologyImplantComplicationbusiness
researchProduct